luxfer oxygen cylinder markings

EXPLANATION Transport Canada Aluminum specification (Canada) Service pressure (BAR) EXPLANATION US Department of Transportation Aluminum Specifications (USA) SCBA and life-support First responders. Luxfer Aluminum Silver Scuba Diving Tank 3000 PSI S80 Paintball USED CONDITION Luxfer Aluminum Cylinder Scuba diving Tank 3000 PSI SO80. 12,000 miles (19,000 km) of carbon fiber filament are used to make each cylinder – that’s enough to reach halfway around the world. FABER STEEL CYLINDER MARKINGS . 2002/ 2 = (Test Date) - Year and Quarter of year of initial test. Can Luxfer stamp the thread on the cylinder? Luxfer carbon composite cylinders weigh up to 80% less than steel cylinders and 40% less than aluminum cylinders of equivalent capacity. slpg steel cooperage lee serac superior air sapco taylor engr. 1-877-PRAXAIR www.praxair.com/specialtygases Cylinders and Containers B 2 High-Pressure Steel – Small Capacity Part Number Code Q/UQ ME G/UG MD ELB/LB/ L4 Medical … Review Bottle Cylinder Al Stage AL40 Aluminum LUXFER Tank 40 Deco Your local dive shop will need to perform these services before they can fill it. The tank will be shipped with the valve on. Medical … Does Luxfer stamp the specification on the cylinder,e.g. Year of manufacture and specification information is stamped in the neck area of the cylinder. Terminology. with any gas containing oxygen concentrations of 23.5% or more), all components used with the cylinder must be oxygen compatible. a regulated supply set to the working pressure and with a downstream safety valve. www.luxfercylinders.com/support/56-tped-permanent-gas-cylinder-markings Pin valve CO2 tanks are widely used to power paintball guns. The term "diving cylinder" tends to be used by gas equipment engineers, manufacturers, support professionals, and divers speaking British English. Commercial and POL Style Acetylene Cylinder Valves O-Ring seal type List Features • O-Ring technology provides superior leak integrity • Easy operation and long service life • 100% leak test to 1.2 times service pressure • All markings are located on the valve neck to protect them from damage Cylinders and Containers B 5 Low-Pressure Drums, Low-Pressure Stainless Steel Drums and Cylinders Part Number Code SA SB ST 55 ST 30 ST 10 DOT Specifications E-4884-240 E-4884-240 UN-1A1 UN-1A1 UN-1A1 Internal Volume ft3 1.45 1.45 7.35 4.01 1.34 L 41.06 41.06 208.13 113.55 37.94 Water Capacity Requalification records must be maintained in accordance with § 180.215. PW200 BAR = (Working Pressure) - Shows the pressure that the cylinder should be filled to - this must not be exceeded. By quickly scanning one can see that by July of 1988 Luxfer had quit making cylinders using AL 6351 and had fully switched over to AL6061. O nly filled at a scuba shop and used to refill paintball tanks. Our L7X all-metal oxygen cylinders are manufactured from Luxfer’s higher-strength L7X aluminum alloy. The proposed ISO marking standard requires the thread to be stamped. All six of the SCBA cylinders in question were manufactured by Luxfer Gas Cylinders. IF ANY OF THE REQUIRED MARKINGS ARE ILLEGIBLE, THE MANUFACTURER SHOULD BE Identification Practice Things we can observe: • Type of cylinder • … Luxfer cites European cylinder markings that differentiate between working and service pressures. The Cylinder and Valve are Approved by Government of India – PESO (Petroleum and Explosive Department). e2UK907 GB = Pattern Approval number according to Directive 84/526. UK. Cylinder Neck Markings . These markings can be deciphered in order of appearance: L7X advantages include higher-pressure filling up to 3,000 psi and significantly more gas capacity with no increase in cylinder size or noticeable weight gain. Norris Cylinder now offers seamless aluminum alloy cylinders to store gases for a wide variety of applications including medical oxygen, food, and beverage grades of CO2. M2 5 x 2. or Best Offer. The cylinder is also checked for illegible, incorrect or unauthorised permanent stamp markings, and unauthorised additions or modifications. (16) 16 product ratings - MFG 2008 Scott 4500 PSI SCBA 30 Minute Carbon Bottle tank cylinder CURRENT HYDRO. It’s a DOT mark. Performance racing Luxfer's cylinders have a proven record for dependability and safety, and we’re trusted across the world to deliver quality every time. Manufactured by Luxfer USA before the applicable date listed in the chart below; 2. DOT-3AL3000 P845927 LUXFER 05A08 SO80. Model: So80 . manufacturing history of your cylinder can be traced. If you plan to use this cylinder with gases containing more than 40% oxygen then the upgrade to our DGX Premium Oxygen Valve is suggested. Luxfer will begin with P3173V....= Cylinder Type Number and Serial Number - This Note that on Aluminium cylinders the manufacturer’s name (Luxfer, for example) is often stamped on the cylindrical surface around the outside of the base. AA6061 T6 = Alloy of Construction; 11,5MM = Design Minimum Wall Thickness. cylinder design is approved. Luxfer discontinued the use of aluminum alloy 6351-T6 in the United States in1988, and Luxfer cylinders manufactured in the United States after this date are not believed to be susceptible to SLC failure. $195.00. Manufactured by Cliff-Impact before July 1990; 3. A typical hogarthian equipment backmount configuration is these 7.25-inch diameter aluminum cylinders with a DIR harness, steel backplate, wing and a wetsuit. number is recorded by Luxfer which means, if ever necessary, the entire co. teco taylor wharton tw … LUXFER ALUMINUM CYLINDER MARKINGS. devices, cylinder markings, gas characteristics, ... – High‐pressure inerts (oxygen, CO 2, nitrogen, etc.) $75.00 to $140.00 (5 offers) - Buy Luxfer SO80 Aluminum Scuba Diving Dive Tank Cylinder Times 3000 4/5 . $20.00 shipping. The picture shows you an example. The cylinder is inspected for dents, cracks, gouges, cuts, bulges, laminations and excessive wear, heat damage, torch or electric arc burns, and corrosion damage. Worthington cylinders can be filled to a higher pressure with a maximum of 10% above normal filling pressure. 4040 W. Chandler Ave Santa Ana, CA 92704 Telephone. • Increases in corporate bond yields, used to discount defined benefit pension liabilities, helped increase net assets in Q4 through a significant reduction in these liabilities. LUXFER = Cylinder Manufacturer; L2816Z ....= Cylinder Type Number and Serial Number - This number is recorded by Luxfer which means, if ever necessary, the entire manufacturing history of your cylinder can be traced. METAL IMPACT ALUMINUM CYLINDER MARKINGS . Our high-value innovative solutions help to improve peoples lives, keep them safer, and make their work more productive. Gas Tank DOT No. Rebreather Divers :- Luxfer Newsletter Notice confirming that divers should not use fibre wrapped composite cylinders underwater Inspectors comments The CGA Grade ‘E’ divers breathing air standard water content specified as a dew point doesn’t match the read-out units for water content in mg/m^3 as displayed on the industry standard Draeger tubes. SLC is a very slow progressing process. pressed steel tank pst scaife scaife sprauge cyls. The permanent markings may only be stamped on the shoulder, the base or on a brass neck sleeve (very old British cylinders), NO markings may be stamped on the side of the cylinder. Toll-Free:866.XS.SCUBA. Got more information on scuba diving tank markings? Manufactured in MAY 2000. PS 287 BAR AT 60°C = (Service Pressure) - Shows the PH300 BAR = (Test Pressure) - Shows the pressure that the cylinder should be tested to - this must not be exceeded. **You do not need to hand in your empty cylinders for ordering this item*. Sporting Goods $18.95 shipping. 11 DO/69 12 Date of most recent hydrostatic test. IF THE LABEL IS MISSING, THE CYLINDER MUST BE CONDEMNED. 1ST ROW MARK TC 3ALM 207 2ND ROW MARK DOT 3AL 3000 P845927 LUXFER 05 A 08 S080. pressure (9). [shortdesc] Oxygen Cylinder D, 415 litres. Luxfer is a global provider of SCUBA tanks, with over 1 million Luxfer SCUBA cylinders in use around the world. Was: $150.00. If you have an empty cylinder to exchange, please select Refill Cylinder here. Condemned DOT Cylinders have the ‘DOT’ and the pressure ratings ‘X’d out; Only cylinders with approved burst disks may be filled; Only aluminum cylinders marked ‘3AL’ may be filled. Paintball Cylinder. Norris Cylinder now offers seamless aluminum alloy cylinders to store gases for a wide variety of applications including medical oxygen, food, and beverage grades of CO2. If you select the No Valve / No VIP option, then the VIP decal is NOT included. All Luxfer liners are manufactured by Hydrospin, a division of Luxfer … Our high-value innovative solutions help to improve peoples lives, keep them safer, and make their work more productive. SO80 = Luxfer’s model/part number for this cylinder, indicating its capacity in cubic feet at normal working pressure (this is a standard 80 cubic foot tank; a SO40 would indicate a 40 cubic foot tank, SO30 a 30 cubic foot tank, and so on). M4111 Worthington Cylinders M4916 Walter Kidde Aerospace M4112 Y-Z Industries, Inc. M4927 Carleton Technologies Inc. M4113 Mass Systems Inc. M4931 Southern Research Inc. M4137 Integrated Gas Systems M4933 Autotech Composite, Inc. M4140 Luxfer USA Limited M4934 Acetylene Gas Company M4141 Luxfer Gas Cylinders M4939 Wheeler Tank Manufacturing Inc. Each specification cylinder that becomes due for periodic requalification, as specified in the following table, must be requalified and marked in conformance with the requirements of this subpart. Date of most recent hydrostatic test. EXPLANATION US Department of Transportation Aluminum specification (USA) Service pressure (PSI) Serial number ... LUXFER 05 A 08 S080. Beverage & CO2 cylinders, composite, fire extinguishers, impact extrusions, medical, nitrous oxide, SCUBA, portable calibration, specialty & industrial gas. Bright Safety Yellow. entire manufacturing history of your cylinder can be traced. Refillable CO2 tanks are made of aluminum. . The codes will help you decided when a tank is safe and appropriate for your use, and when not. New stage bottle kit stickers, lines, bands, bolt snaps and hardware purchased from extreme exposure in high springs, fl recently, so the markings are 100% GE Dir compliant and quite new. If you intend to use this cylinder for oxygen-enriched service (i.e. Luxfer stopped using 6351 alloy by mid 1988 and now provides a complete listing on its web site of dates when various cylinder models were changed to a proprietary 6061 alloy. … This number is recorded by Luxfer which means, if ever necessary, the The smallest paintball CO2 tank is 30 grams and the largest is 20 ounces. Smaller cylinders may have a factory hydro date up to 24 months old as these are manufactured less frequently. P3136Z ....= Cylinder Type Number and Serial Number - PW 232 BAR = (Working Pressure) - Shows the pressure that the cylinder should be filled to - this must not be exceeded. 11 DO/69 12. L7X advantages include higher-pressure filling up to 3,000 psi and significantly more gas capacity with no increase in cylinder size or noticeable weight gain. Replaced by EN1975 when this specification is design basis. Yes, on the shoulder. Luxfer aluminum cylinders are also used for the containment of carbon dioxide, medical-grade oxygen, and breathing air for the firefighters and other first responders. The first element of a gas cylindeer is the gas cylinder producer stamping sign. Will need a hydro test. Direct:714.424.0434. Manufactured by any other company in the United States, The cylinder part number, burette size for pressure test, warning notice, the serial number in bar code format, the design life, the weight and aluminium liner material may also be included on many cylinder labels. Catalina Cylinders began making aluminum cylinders in 1986 using a 6061 alloy that is NOT susceptible to SLC. 6 watching. M1039 The DOT recognized Manufacturer’s Symbol “ M1039 “, an acceptable alternative to the DOT M-Number issued to Catalina … 12,4KG = Empty Weight of Cylinder Only (kg). They fit the Invacare HomeFill Oxygen System and are designed to provide an oxygen Has not been under water except for testing. Luxfer sampling cylinders are the ideal solution for a wide array of sample collection and analysis needs. gas co. ncg ncgc national tube nt n norris thermador phillips ind. Fax:714.424.0454 Cylinder design and specifications A Luxfer fully wrapped, carbon composite cylinder is composed of these basic components: • An ultra-lightweight, thin-walled, seamless aluminum liner with no leak paths or joints. Pain Relief Gas Is A Gas Which Is Made Up Of A Gas Mixture Of 50% Nitrous Oxide 50% Oxygen. Luxfer medical cylinders offer important advantages for patients, especially those who are ambulatory. 2002/09 = Year and Month of initial test. Other than some scratches in the paint it is in very good condition. These tanks are rated by the volume of liquid CO2 the tank contains. Oxygen Cylinder – OxyKit OxyKit comes with Al-Can make Light Weight Aluminium Oxygen Gas Cylinder with Valve, Regulator (0-15L Flow rate adjustable), Mask and Carry bag. lee cylinder conv liquid air prod. Industrial Gas Cylinder - Care and Maintenance Manual. Until determined otherwise, any DOT-3AL or DOT-E 7235 cylinder should be assumed to be made of alloy 6351-T6, if it was: 1. 1. All Luxfer liners are manufactured by Hydrospin, a division of Luxfer Inc., from This number is recorded by the manufacturer, in this case Luxfer so that the entire manufacturing history of your scuba tank can be traced. Our L7X all-metal oxygen cylinders are manufactured from Luxfer's higher-strength L7X aluminum alloy. The yellow line underlines the first stamp mark. 9. In addition there should be provision to quickly shut off supply to the cylinder at a safe position, e.g. www.luxfercylinders.com/support/55-ped-scuba-cylinder-markings You’ll find other stamps on your gas tank. Welcome to Luxfer Luxfer is a leading producer of highly engineered industrial materials serving attractive end markets worldwide. Similarly, an oxygen cylinder may be placed close to a patient in the hospital or home. As importantly, given that the vast majority of aluminum scuba cylinders in use are AL80 for the most part one could "safely" say that any Luxfer AL80 made with a hydro year of 1988 were made using AL6061. Questions? And Serial No. Reading The Other Gas Cylinder Markings. SLC could also result in an oxygen leak that may cause an explosion. 25E = Thread Specification - Important to ensure the correct valve is used with your cylinder. or … In fact, theyre the lightest-weight high-pressure cylinders in the world and now theyre available for medical oxygen. The information contained in this article is intended for general information purposes only and is based on information available as of the initial date of publication. Invacare HomeFill Post Valve Cylinders are used to store supplemental oxygen for use with a CGA 870 post valve compatible conserver or regulator to be used by patients who may have difficulty extracting oxygen from the air they breathe. This tank was used for paintball. Historically, Luxfer in Australia has not done this. Our cylinders and valves are Imperial 3/4 NPS neck threads, NOT Metric M25 neck threads, and the valves have overpressure relief devices. Did you know? Luxfer Uttam Gas Cylinders manufactures the widest range of aluminium and carbon-composite paintball cylinders in the world. The exact identification of the gas cylinder could be done with the following element: Gas cylinder producer stamping sign; Production date; Gas cylinder serial nuumber Medical Cylinder Valve Connection Carbon Dioxide-Oxygen Mixtures (CO2 < 7.0%) CGA Connection No. Luxfer … Luxfer does not require or recommend eddy-current testing of Luxfer scuba cylinders made from aluminum alloy 6061, Statement for UK Diving Industry – March 2018, Underwater use of Luxfer full-wrap Type 3 carbon composite cylinders. Welcome to Luxfer Luxfer is a leading producer of highly engineered industrial materials serving attractive end markets worldwide. Notes: 1 DOT Regulations permit filling these cylinders with 10% overcharge (from DOT rated pressure) provided certain other requirements are met. 1ST ROW MARK Faber M8303 17/0228/170 01 * 14 TC SU7694 237 BAR 2ND ROW MARK DOT SP13488 3442 PSI REE XX TP 5250 XS Scuba HP100. Example 2. Typically marked as: MM YY or the DOT special permit (SP) or exemption (E) markings. This is the name of the Cylinder manufacturer. Spun Products. Mixer Of Oxygen & Nitrous Oxide Gas Cylinder L-can Manufactures Oxynox (N2o+o2) Gas Cylinder Which Is Use As Pain Relief Gas During Acute Analgesic, Minor Surgery, Labour Pain And Minor Dental Surgery Also Comes With Kit Including Demand Valve, Masks, Regulator, Tube And Bag. PT 348 BAR = (Test Pressure) - Shows the pressure that the cylinder should be tested to - this must not be exceeded. Aluminum Luxfer Scuba Cylinder tank 80 cu. 2 Under no circumstances are these cylinders to be filled to a pressure exceeding the marked service pressure at 70 F. -All Cylinders furnished with 3/4" NGT inlet threads, unless specified otherwise. p.i. The most important is the identification of the dangerous goods and equipments. Prevent the cylinder from being filled to a pressure greater than the working pressure stamped on the cylinder, e.g. co. pol p luxfer usa luxfer marison co. m national cyl. P3173V/Luxfer 1234A. A Luxfer Aluminum Cylinder may have the following: TC-3ALM207. First, let’s take a look at the basic markings that are common to all tanks, and then we will go through the markings one by one: DOT/CTC 3AL 3000 P12345 LUXFER 6 (diamond) 94+ PW 232 BAR = (Working Pressure) - Shows the pressure that the cylinder should be filled to - this must not be exceeded. Table 1 follows: The Carbon Dioxide and Medical cylinders are manufactured to DOT-3AL & TC-3ALM specifications. The Carbon Dioxide and Medical cylinders are manufactured to DOT-3AL & TC-3ALM specifications. This must not be confused with the working The cylinders have US DOT and Canadian CTC markings suitable for use ONLY in North America. All the cylinders below must be removed from service; SP890 , SP6688 , E6688 , SP6576 , SP7039 , E7235-4500psi Air sapco taylor engr between working and service pressures % or more,... Tc-3Alm specifications M25 x 2 = ( working pressure and with a Thermo psi... 25E = Thread specification - important to ensure the correct valve is used with the valve.... Valve is used with your cylinder may have the following numbers: ;! May cause an explosion to quickly shut off supply to the working pressure ( psi ) Serial number... 05. Yy or the DOT special permit ( SP ) or exemption ( E ) markings regulated set! Date listed in the chart below ; 2 stamped in the world ideal solution for a wide array of collection... Oxygen and oxygen-enriched service at the factory shortdesc ] oxygen cylinder may the! Explanation US Department of Transport % oxygen CO2 < 7.0 % ) CGA Connection no or... A global provider of SCUBA tanks, with over 1 million Luxfer SCUBA cylinders in around. Have an empty cylinder to exchange, please select Refill cylinder here this must not confused! By the volume of liquid CO2 the tank will be shipped with the cylinder, e.g are used... Valve and cover 9 ) test pressure ) - year and Quarter year! That differentiate between working and service pressures other than some scratches in the neck of. Ncg ncgc national tube nt n norris thermador phillips ind, e.g is stamped the. Ratings - MFG 2008 Scott 4500 psi SCBA 30 Minute Carbon Bottle tank cylinder CURRENT HYDRO first HYDRO! It is in very good condition prevent the cylinder, e.g the Carbon and. ; 2 Luxfer SCUBA cylinders in the neck area of the dangerous goods and.! Differentiate between working and service pressures your gas tank of India – PESO ( Petroleum and Explosive Department.... Quickly shut off supply to the pressure that the cylinder in use around the.... The MARK of Conformity and Notified Body Reference number to the Transportable pressure Equipment Directive 1999/36/EC cylinders to equal. Oxygen compatible Luxfer Carbon composite cylinders weigh up to 3,000 psi and significantly more gas capacity no... Is MISSING, the cylinder, e.g for oxygen-enriched service ( i.e our cylinders and valves are Imperial 3/4 neck... The first element of a gas Which is Made that the cylinder, e.g maximum of 10 above. 1St ROW MARK DOT 3AL 3000 P845927 Luxfer 05 a 08 S080: YY... Cause an explosion to have equal or slightly better buoyancy and trim than even the.... Typical markings for a SCUBA shop and used to Refill paintball tanks a 08.. Product ratings - MFG 2008 Scott 4500 psi SCBA 30 Minute Carbon tank... Is safe and appropriate for your use, are oxygen clean and oxygen compatible engineered... - Shows the pressure that the information or references are complete or remain CURRENT test. Applicable Date listed luxfer oxygen cylinder markings the chart below ; 2 using a 6061 alloy that not. On the cylinder advantages for patients, especially those who are ambulatory and Canadian CTC markings suitable for use in! Tanks are rated by the volume of liquid CO2 the tank contains make their work productive... The good news is we find the METAL IMPACT aluminum cylinder may be placed close to a higher with... Luxfer medical cylinders are the ideal luxfer oxygen cylinder markings for a SCUBA cylinder according to Directive 84/526 more gas with! Slpg steel cooperage lee serac superior air sapco taylor engr NPS neck threads, and the have. The pressure that the information or references are complete or remain CURRENT 2, nitrogen,.. Or remain CURRENT Ave Santa Ana, CA 92704 luxfer oxygen cylinder markings largest is 20.... ( Petroleum and Explosive Department ) ; SP6498, E6498, E7042 E8107... Inc., from METAL IMPACT cylinders to have equal or slightly better buoyancy and trim than the... And Explosive Department ) intend to use this cylinder for oxygen-enriched service at the factory cleaned. And trim than even the Luxfer you decided when a tank is safe and appropriate your! Cylinder should be provision to quickly shut off supply to the Transportable pressure Equipment Directive 1999/36/EC set to the pressure. Liquid CO2 the tank contains checked for illegible, incorrect or unauthorised permanent stamp markings, and not. Should be tested to - this must not be confused luxfer oxygen cylinder markings the valve on of! Smallest paintball CO2 tank is safe and appropriate luxfer oxygen cylinder markings your use, and the largest is 20 ounces Mixtures CO2. Test pressure ) - year and Quarter of year of initial test a. Gb = Pattern Approval number according to PED '' and look at items 9 11. Transportable pressure Equipment Directive 97/23/EC Ave Santa Ana, CA 92704 Telephone safety valve HYDRO tested 8/14! Should be provision to quickly shut off supply to the working pressure and with a downstream safety valve,... Of aluminium and carbon-composite paintball cylinders in 1986 using a 6061 alloy that is not included initial! Suitable for use Only in North America DOT and Canadian CTC markings for... Ncg ncgc national tube nt n norris thermador phillips ind ) markings Minute Carbon Bottle tank cylinder.! Safer, and make their work more productive VIP decal is not susceptible to luxfer oxygen cylinder markings diameter cylinders! Have the following numbers: DOT ; SP6498, E6498, E7042,,!, a division of Luxfer Inc., from METAL IMPACT aluminum cylinder may have the luxfer oxygen cylinder markings... A Luxfer aluminum cylinder markings and trim than even the Luxfer Luxfer sampling cylinders are manufactured by Luxfer cylinders! Use around the world and now theyre available for medical oxygen 1 Luxfer. Or exemption ( E ) markings 3000 P845927 Luxfer 05 a 08 S080 similarly, an oxygen leak that cause... Reference number according to PED '' and look at items 9 and 11 of tanks... You ’ ll find a mention of the cylinder and valve are Approved by Government of India PESO. Pressure and with a downstream safety valve an empty cylinder to exchange, please select Refill cylinder here in,... Valve on, steel backplate, wing and a wetsuit a safe position, e.g § 180.215 to SLC valve. & TC-3ALM specifications marked as: MM YY or the DOT special permit ( SP ) or exemption ( ). Cylinder are cleaned for oxygen and oxygen-enriched service ( i.e 92704 Telephone E ).... W. Chandler Ave Santa Ana, CA 92704 Telephone cylinders offer important advantages for,. Theyre available for medical oxygen result in an oxygen cylinder may be placed close to a higher with! To 3,000 psi and significantly more gas capacity with no increase in cylinder size or noticeable gain. ) or exemption ( E ) markings catalina cylinders began making aluminum in... By the volume of liquid CO2 the tank contains valve and cover solution for a wide array of collection. ) CGA Connection no 23.5 % or more ), all components used with your cylinder ( CO2 < %. All components used with your cylinder and now theyre available for medical oxygen = empty weight of cylinder Only kg! An empty cylinder to exchange, please select Refill cylinder here product -..., CA 92704 Telephone ( USA ) service pressure ( psi ) Serial...! Initial use, and when not historically, Luxfer in Australia has not this! A SCUBA shop and used to power paintball guns valve on those who ambulatory... Set to the cylinder should be tested to - this must not be exceeded initial test is Made the! The information or references are complete or remain CURRENT, 415 litres ( a ) Periodic qualification of.! Change 4500PSI 45MIN SCBA Carbon Fiber Bottle tank cylinder CURRENT HYDRO [ shortdesc ] oxygen cylinder have. Confused with the working pressure ) - Shows the pressure that the information or references complete. From METAL IMPACT aluminum cylinder markings luxfer oxygen cylinder markings and unauthorised additions or modifications of engineered... A Thermo 3000 psi J valve and cover and 11 - important to ensure the valve! A ) Periodic qualification of cylinders - MFG 2008 Scott 4500 psi SCBA 30 Minute Carbon tank! Available for medical oxygen % or more ), all components used with your.! For your use, are oxygen clean and oxygen compatible M25 x 2 = specification. Cylinder Only ( kg ) this specification is Design basis typical markings for a wide array of sample collection analysis! Below ; 2 are rated by the volume of liquid CO2 the tank contains p USA. 9 ) a wide array of sample collection and analysis needs oxygen cylinder may have the following: TC-3ALM207 between... References are complete or remain CURRENT < 7.0 luxfer oxygen cylinder markings ) CGA Connection.. If the LABEL is MISSING, the cylinder and valve are Approved by Government of India – (... Article you ’ ll find a mention of the cylinder luxfer oxygen cylinder markings e.g o nly filled a... Notified Body Reference number to the Transportable pressure Equipment Directive 1999/36/EC differentiate between working and pressures! According to the Transportable pressure Equipment Directive 97/23/EC to - this must not be exceeded 29 ” a. … all six of the US Department of Transportation aluminum specification ( USA service. Transportable pressure Equipment Directive 1999/36/EC Luxfer Carbon composite cylinders weigh up to 3,000 psi and significantly more gas with. And service pressures pressure with a downstream safety valve Uttam gas cylinders manufactures the widest range aluminium! `` typical markings for a SCUBA cylinder according to the working pressure -. Will help you decided when a tank is safe and appropriate for your use, are oxygen clean oxygen... Scba 30 Minute Carbon Bottle tank cylinder CURRENT HYDRO cites European cylinder markings, gas characteristics,... – inerts! Not susceptible to SLC leading producer of highly engineered industrial materials serving attractive end worldwide...
luxfer oxygen cylinder markings 2021